Commercial Rooftop Unit (RTU) Sizing Calculator

🏢 Commercial Cooling Tonnage, RTU Staging & CFM

Size commercial HVAC for offices, retail, restaurants, server rooms and warehouses. Get the required cooling tonnage, a recommended rooftop unit (RTU) staging combination, and the fresh-air ventilation CFM — factoring business type, occupancy, internal heat loads, ceilings and climate.

🏢1. Building Type

Each building type carries a different internal heat load — a restaurant kitchen or server room runs far hotter than an office or warehouse.

📐2. Floor Area & Ceiling

sq ft

Range: 500 – 50,000 sq ft

👥3. Occupancy & Internal Loads

people

Auto-set from building type & area — adjust to your peak headcount.

🌍4. Climate & Unit Staging

Multiple staged RTUs give redundancy (if one fails, the building stays partly cooled) and better part-load efficiency — the commercial standard.

Advertisement
Commercial Load
0 Tons

Commercial AC Tonnage by Building Type & Size

Commercial cooling isn't one-size-fits-all — a restaurant needs 3–4× the tonnage of a warehouse of the same size because of kitchen, lighting and occupancy heat. This chart shows typical cooling loads; use the calculator above for your exact staging and CFM.

Building TypeRule of ThumbTypical Load (per 1,000 sq ft)
Office / Professional1 ton per ~350 sq ft~2.8 Tons
Retail Store1 ton per ~250 sq ft~4.0 Tons
Restaurant / Kitchen1 ton per ~150 sq ft~6.5 Tons
Server / IT Room1 ton per ~150 sq ft~6.5 Tons
Warehouse / Industrial1 ton per ~600 sq ft~1.7 Tons

These are planning rules of thumb for packaged rooftop units (RTUs) at standard ceilings. High ceilings, hot climates, heavy glazing, dense occupancy and process equipment push tonnage up — the calculator factors all of it.

Advertisement

How Commercial RTU Sizing Works

Commercial load estimation follows ACCA Manual N and ASHRAE guidance. The calculator combines four load sources, then adds a safety and ventilation layer.

1. Building Envelope Load

Floor area × a per-square-foot factor for the building type × a ceiling-height multiplier. Taller ceilings mean more air volume to cool, so a 20 ft warehouse carries a higher factor than an 8 ft office.

2. Occupancy & Equipment (Internal Gains)

Each person adds about 400 BTU/hr of body heat, which matters enormously in dense spaces like restaurants and retail. Lighting and equipment add another layer — a commercial kitchen or gym generates several times the heat of an office.

3. Sun, Glazing & Climate

Large storefront glass and hot Sun-Belt or humid-South climates raise the load with multipliers. An internal server room with no windows in a northern climate sits at the low end; a west-facing restaurant in Phoenix sits at the top.

4. RTU Staging & Ventilation

Commercial buildings rarely use one giant unit. The calculator splits the load into multiple standard RTUs (3, 4, 5, 6, 7.5, 10 ton…) so that if one fails the building stays partly cooled, and part-load efficiency improves. It also computes the fresh-air CFM your ventilation must supply (ASHRAE 62.1) and the total supply airflow at ~400 CFM/ton.

Frequently Asked Questions

How many tons of commercial AC do I need per square foot?
It depends on the building type. A standard office needs about 1 ton per 350 sq ft; retail ~1 ton per 250 sq ft; restaurants and server rooms ~1 ton per 150 sq ft (high internal heat); and warehouses ~1 ton per 600 sq ft. Use the calculator above to factor ceilings, occupancy, equipment and climate.
Why do commercial buildings use multiple RTUs instead of one large unit?
Multiple staged rooftop units provide redundancy — if one unit fails, the building stays partially cooled instead of going fully offline. They also allow zoning for different areas and run more efficiently at partial load. That's why the calculator recommends a staged combination (e.g. two 5-ton RTUs) for larger loads.
What size RTU do I need for a 2,000 sq ft restaurant?
A 2,000 sq ft restaurant typically needs about 13–16 tons of cooling because of the kitchen, lighting and dense occupancy — far more than an office of the same size. That's usually staged as two RTUs (e.g. a 7.5-ton plus a 6-ton). Enter your exact details above for a precise figure.
How is commercial fresh-air ventilation (CFM) calculated?
Under ASHRAE 62.1, fresh-air requirement ≈ (people × 15 CFM) + (floor area × 0.06 CFM/sq ft). The calculator computes this automatically. Total supply airflow is separate — roughly 400 CFM per ton of cooling.
What's the difference between an RTU and a split system?
A rooftop unit (RTU) is a self-contained packaged system — compressor, coil and air handler in one cabinet on the roof — standard for commercial buildings. A split system separates the condenser and indoor unit. RTUs are easier to stage, service and replace on commercial roofs, which is why they dominate offices, retail and restaurants.
Do I still need an engineer if I use this calculator?
Yes. This is a planning and budgeting estimate. Any commercial installation needs a stamped Manual N / ASHRAE design from a licensed mechanical engineer that accounts for your exact envelope, ductwork, process loads and local code. Use this tool to scope the project and sanity-check contractor proposals.

Related tools from Refcon HVAC

Last updated: 2026. Reviewed by the Refcon HVAC engineering team using ACCA Manual N & ASHRAE 62.1 guidance. Planning estimate — confirm with a licensed commercial mechanical engineer. Tell us about an error.

Advertisement
Before you decide — three quick things
Get real quotes
Estimates vary by contractor. Compare free quotes from licensed local pros before you commit. Request a quote →
Check rebates & credits
High-efficiency systems may qualify for utility rebates and federal or state incentives. Find current programs at ENERGY STAR & DSIRE.
Reviewed for accuracy
Figures are reviewed by the Refcon HVAC engineering team using U.S. DOE, ENERGY STAR & ACCA Manual J data. Estimates only — confirm with a licensed pro.
📋 Embed this free calculator on your website

Run a website? Add this live calculator to any page — free to use. Your visitors get the tool, and you credit the source with a link back.