Restaurant AC Sizing Calculator

Need to size the air conditioning for a restaurant? Restaurant dining areas run hot: kitchen heat spills into the space, diners and staff add body heat, and doors open constantly. That pushes the cooling factor to about 35 BTU/sq ft — well above a normal room — so restaurant AC has to be sized generously to keep guests comfortable during a busy service. The calculator below is pre-set to a restaurant at 1,000 sq ft — a restaurant that size typically needs about a 4 Ton AC (42,350 BTU/hr, 12.4 kW) in a moderate climate. Enter your own area for an instant answer.

🧊 Find the Right AC Size for Your Room — in Tons & BTU

Convert room size (sq ft or m²) to the exact AC tonnage you need — 0.5, 1, 1.5, 2 Ton and up. ACCA Manual-J inspired, in tons, BTU/hr and kW, for the US, UK, Europe, India, UAE, Saudi Arabia & Australia.

🌍 Prefer metric? Switch units here

🏠1. Space Type

📐2. Floor Area & Ceiling

sq ft

Range: 50 – 10,000 sq ft

ft

Range: 7 – 20 ft

people

Range: 0 – 50 people

🌍3. Country / Climate

The base factor assumes a 30 °C / 86 °F design day. Change the chip above to match your region.

🧱4. Insulation

☀️5. Sun Exposure

🪟6. Windows / Glazing

Advanced loads (kitchen, appliances, exhaust) — optional

Wattage × 3.4 = BTU/hr. e.g. 500 W ≈ 1,700 BTU/hr

For office IT, gym gear, lab equipment

Advertisement
Recommended AC
0 BTU/hr
0.00 Tons

Restaurant AC Size by Floor Area

Typical AC tonnage for a restaurant with an 8-foot ceiling and average conditions. Heavy equipment, high occupancy, or a hot climate will push these up — adjust those in the calculator:

Restaurant SizeRecommended ACApprox. BTU/hr
500 sq ft2 Ton21,175 BTU/hr
800 sq ft3 Ton33,880 BTU/hr
1,000 sq ft4 Ton42,350 BTU/hr
1,500 sq ft5 Ton63,525 BTU/hr
2,000 sq ft5 Ton84,700 BTU/hr
Advertisement

Sizing AC for a Restaurant — What to Consider

Keep the kitchen on its own exhaust and make-up air system, separate from the dining-area AC. Account for peak occupancy (people add ~600 BTU/hr each above the base) using the occupants field, and plan for the door-traffic heat gain in high-footfall venues. The calculator applies the restaurant heat-gain factor automatically; use the advanced fields (occupants, equipment, appliances, ventilation) to match your exact space, and remember an oversized unit short-cycles and dehumidifies poorly — right-sizing gives better comfort and lower running cost.

Frequently Asked Questions

What size AC do I need for a restaurant? A 1,000 sq ft restaurant typically needs about a 4 Ton AC (42,350 BTU/hr) in a moderate climate; scale up or down with your floor area per the chart above.

How do you size AC for a restaurant? Size the dining area at roughly 35 BTU/sq ft plus occupant load, and keep the kitchen on separate exhaust and make-up air. A 1,000 sq ft dining room typically needs about 4 tons.

How many BTU per square foot for a restaurant? Roughly 35 BTU/sq ft as a starting factor, before adjusting for climate, ceiling height, occupancy, and equipment heat.

Advertisement

Background reading: how the refrigeration cycle works.

Before you decide — three quick things
Get real quotes
Estimates vary by contractor. Compare free quotes from licensed local pros before you commit. Request a quote →
Check rebates & credits
High-efficiency systems may qualify for utility rebates and federal or state incentives. Find current programs at ENERGY STAR & DSIRE.
Reviewed for accuracy
Figures are reviewed by the Refcon HVAC engineering team using U.S. DOE, ENERGY STAR & ACCA Manual J data. Estimates only — confirm with a licensed pro.