What size commercial AC do you need for a 2,000 sq ft Restaurant? A restaurant of this size carries a very high internal heat load (kitchen heat and dense dining occupancy), so it typically needs about 13.8 tons of cooling — best installed as 2 × 7.5-Ton RTUs for redundancy — plus about 1,125 CFM of fresh air (ASHRAE 62.1). The calculator below is pre-set to this space.
Commercial Cooling Loads for a Restaurant
Sizing an air conditioning system for a Restaurant is drastically different from residential Manual J calculations. A Restaurant introduces specific, high-intensity internal heat gains—from specialized equipment, concentrated lighting, changing occupancy densities, and strict ventilation codes requiring fresh outside air. You cannot use a generic square-footage rule of thumb. Use the commercial calculator below to account for these heavy sensible and latent heat loads to ensure your facility maintains a comfortable, safe, and code-compliant environment.
🏢 Commercial Cooling Tonnage, RTU Staging & CFM
Size commercial HVAC for offices, retail, restaurants, server rooms and warehouses. Get the required cooling tonnage, a recommended rooftop unit (RTU) staging combination, and the fresh-air ventilation CFM — factoring business type, occupancy, internal heat loads, ceilings and climate.
🏢1. Building Type
Each building type carries a different internal heat load — a restaurant kitchen or server room runs far hotter than an office or warehouse.
📐2. Floor Area & Ceiling
Range: 500 – 50,000 sq ft
👥3. Occupancy & Internal Loads
Auto-set from building type & area — adjust to your peak headcount.
🌍4. Climate & Unit Staging
Multiple staged RTUs give redundancy (if one fails, the building stays partly cooled) and better part-load efficiency — the commercial standard.
2,000 Sq Ft Restaurant Cooling Load by Climate
The same 2,000 sq ft Restaurant needs more cooling in a hotter climate. Recommended tonnage and RTU staging:
| Climate | Cooling Load | Recommended RTUs |
|---|---|---|
| Northern / Mild | 13.8 tons | 2 × 7.5-Ton RTUs |
| Humid South | 15.1 tons | 2 × 8.5-Ton RTUs |
| Sunbelt / Desert | 15.8 tons | 2 × 8.5-Ton RTUs |
Why a 2,000 Sq Ft Restaurant Needs 13.8 Tons
Commercial cooling load comes from four sources: the building envelope (2,000 sq ft × a per-square-foot factor × ceiling height), occupancy (about 67 people here at 400 BTU/hr each), equipment & lighting, and sun/climate. For a restaurant, the very high internal load from kitchen heat and dense dining occupancy is the deciding factor — which is why it needs far more cooling than an office of the same size. Commercial installs almost always use staged rooftop units (2 × 7.5-Ton RTUs) so the building stays partly cooled if one unit fails. Fresh-air ventilation adds 1,125 CFM (ASHRAE 62.1), and total supply airflow is about 5,501 CFM.
Frequently Asked Questions
What size AC does a 2,000 sq ft Restaurant need? About 13.8 tons of cooling in a moderate climate — roughly 145 sq ft per ton — typically installed as 2 × 7.5-Ton RTUs. Hotter climates push this higher.
How many rooftop units for a 2,000 sq ft Restaurant? We recommend 2 × 7.5-Ton RTUs (15 tons installed). Multiple staged RTUs give redundancy and better part-load efficiency than one large unit.
How much fresh air (CFM) does a 2,000 sq ft Restaurant need? About 1,125 CFM of outdoor air under ASHRAE 62.1, based on ~67 occupants plus floor area. Total supply airflow is around 5,501 CFM.
Related: the fundamentals of industrial refrigeration.
Estimates vary by contractor. Compare free quotes from licensed local pros before you commit. Request a quote →
High-efficiency systems may qualify for utility rebates and federal or state incentives. Find current programs at ENERGY STAR & DSIRE.
Figures are reviewed by the Refcon HVAC engineering team using U.S. DOE, ENERGY STAR & ACCA Manual J data. Estimates only — confirm with a licensed pro.